Telecom Sites Multiple Cabinet System With Cooling Units Micro Data Center

  • 1
  • 2
  • 3

Brand Name : COOLNET

Model Number : ERX

Certification : CE ISO

Place of Origin : CHINA

MOQ : 1PCS

Price : USD3000-10000/PCS

Payment Terms : L/C, T/T

Supply Ability : 200 SETS PER MONTH

Delivery Time : 20-35 working days

Packaging Details : Standard export package

Product Type : All-in-one data center

Refrigerant : R134a/R407C/R22/R410A

Application area : Network closets or telecom sites , Edge Computing

Voltage : 380v/220v,110-220v/50-60Hz,220V/50Hz

Operating power : 380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V

Cabinet type : 26U 42U

Contact Now

Multiple Cabinet System With Cooling Units Micro Data Center For Telecom Sites

Product Introduction

The integrated smart cabinet deeply integrates data center infrastructure products, such as UPS, power distribution, refrigeration, cabinets, fire protection and other subsystems. The monitoring system implements overall management of the entire system and simplifies the design and construction process. Compared to ordinary computer rooms, the integrated cabinet can shorten the construction period, improve the compatibility between systems, and maximize the space utilization of the user computer room. Telecom Sites Multiple Cabinet System With Cooling Units Micro Data Center

Advantage

Telecom Sites Multiple Cabinet System With Cooling Units Micro Data Center

Simpler
Integrate the infrastructure through the idea of ​​productization and modularization. You only need to select the appropriate one according to the space capacity requirements of the IT equipment
The product specifications are sufficient, and there is no need to calculate and design the subsystems, which greatly simplifies the design process.

More time-saving
The product-oriented design allows the IC series cabinet-type smart data center to be installed and delivered within one day on site, compared to traditional construction models. It is more than 2 times faster than traditional data center.

Dust-proof

The biggest advantage of the mini-intelligent computer room is enclosed and dust-proof. The internal air of the computer room can reach the air cleanliness standard of the A-level computer room, the failure rate of IT equipment is greatly reduced, and the life cycle is extended by 1 to 2 times.


More noise reduction

Noise test case: Place 4 rack-mounted servers, 2 switches and other equipment in a common cabinet, and the test room noise is about 75dB;

The same IT equipment is placed in the MICROOM, the test noise is reduced to about 50dB, the noise intensity is reduced by 25 dB, and the noise reduction is about 85%.

Features

  • The box has the characteristics of dust-proof, sun-proof, rain-proof, etc., and is fully adaptable to the outdoor environment.
  • The equipment warehouse cabinet adopts ventilation and heat dissipation.
  • Each cabinet is equipped with DC lighting fixtures.
  • The cabinet has sensing ability and environmental monitoring function, which can realize and upload alarms such as power failure, power failure, access control, temperature, humidity, smoke, water immersion, and battery voltage.
  • The layout of the cabinet is reasonable, the cable introduction, fixing and grounding are convenient for operation and maintenance. Power cables, signal cables and fiber optic cables have separate entry holes and will not interfere with each other.
  • The cables used in the cabinet are made of flame-retardant materials.
Telecom Sites Multiple Cabinet System With Cooling Units Micro Data Center


Technical Parameter

Model EC08 EC12 EC20 ERx
Power 3KVA 3-6KVA 6-30KVA
Number of cabinets 0.8m high cabinet, available space 8U 1.2m high cabinet, available space 16U Standard 42U cabinet, free space 30U 2-10 standard 42U glass door cabinets
Enclosed cabinet Glass door, IP5X, full cold and hot channel sealing
Power supply 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
Refrigeration Unique air duct design, without air conditioner and outdoor unit Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
Monitor 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring

Factory View

Telecom Sites Multiple Cabinet System With Cooling Units Micro Data Center

Delivery and Installation

Telecom Sites Multiple Cabinet System With Cooling Units Micro Data Center

Telecom Sites Multiple Cabinet System With Cooling Units Micro Data Center


Product Tags:

Micro Data Center Smart Cabinet

      

Cooling Units Multiple Cabinet System

      
Wholesale Telecom Sites Multiple Cabinet System With Cooling Units Micro Data Center from china suppliers

Telecom Sites Multiple Cabinet System With Cooling Units Micro Data Center Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hefei Coolnet power Co., ltd
*Subject:
*Message:
Characters Remaining: (0/3000)